LT Brochure
9/4/07 (PDF: 343KB / 6 pages) Version: 0506 Description: Benefits, how it works, features, performance and system design for the Model LT Low Temperature Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
Ceiling Approaches
9/4/07 (PDF: 1MB / 6 pages) Version: 0407 Description: Adaptor frames and options for other than lay in ceilings. |
|
|
|
ST Brochure
9/4/07 (PDF: 799KB / 4 pages) Version: 0604 Description: Benefits, how it works, features, performance and system design for the Model ST Therma-Fuser diffuser. |
|
Round ST Brochure
9/8/09 (PDF: 1MB / 4 pages) Version: 0909 Description: Benefits, how it works, features, performance and system design for the Model STR Round Therma-Fuser diffuser. |
|
|
ST IBM
6/13/08 (PDF: 868KB / 6 pages) Version: 0510 Description: Installation, balancing, maintenance and operation of the Model ST Therma-Fuser diffuser. |
|
STR IOM
9/8/09 (PDF: 186KB / 6 pages) Version: 0909 Description: Installation, balancing, operation and maintenance of the Model STR Round Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
R-Rings ST, TF, TB
9/4/07 (PDF: 296KB / 2 pages) Version: 0606 Description: Bypass R-Rings are used to bypass supply air into the ceiling plenum when Therma-Fuser VAV diffusers turn down. |
|
Ceiling Approaches
9/4/07 (PDF: 1MB / 6 pages) Version: 0407 Description: Adaptor frames and options for other than lay in ceilings. |
|
|
STR-HC Specification
9/8/09 (Word: 100KB / 1 pages) Version: 0909 Description: Performance specification suitable for Part 2 of CSI Specification Section 15840. |
|
|
STR Performance Ratings I-P
9/8/09 (PDF: 26KB / 1 pages) Version: 0909 Description: Static pressure vs. air volume, throw and sound data (inch-pound) for the STR-HC Round Therma-Fuser diffuser. |
|
STR Performance Ratings SI
9/8/09 (PDF: 26KB / 1 pages) Version: 0909 Description: Static pressure vs. air volume, throw and sound data (metric) for the STR-HC Round Therma-Fuser diffuser. |
|
|
|
TB Brochure
3/2/09 (PDF: 1MB / 4 pages) Version: 0911 Description: Benefits, how it works, features, performance and system design for the Model TB Therma-Fuser diffuser. |
|
|
TB IBM
9/4/07 (PDF: 1MB / 4 pages) Version: 0707 Description: Installation, balancing, maintenance and operation of the Model TB Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
R-Rings ST, TF, TB
9/4/07 (PDF: 296KB / 2 pages) Version: 0606 Description: Bypass R-Rings are used to bypass supply air into the ceiling plenum when Therma-Fuser VAV diffusers turn down. |
|
Ceiling Approaches
9/4/07 (PDF: 1MB / 6 pages) Version: 0407 Description: Adaptor frames and options for other than lay in ceilings. |
|
TB Blow Patterns
9/4/07 (PDF: 84KB / 2 pages) Version: 0188 Description: Options and Accessories for the Model TB Therma-Fuser diffuser. |
|
|
|
TF Brochure
9/4/07 (PDF: 367KB / 4 pages) Version: 0406 Description: Benefits, how it works, features, performance and system design for the Model TF Therma-Fuser diffuser. |
|
|
TF IBM
9/4/07 (PDF: 720KB / 4 pages) Version: 0606 Description: Installation, balancing, maintenance and operation of the Model TF Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
R-Rings ST, TF, TB
9/4/07 (PDF: 296KB / 2 pages) Version: 0606 Description: Bypass R-Rings are used to bypass supply air into the ceiling plenum when Therma-Fuser VAV diffusers turn down. |
|
Ceiling Approaches
9/4/07 (PDF: 1MB / 6 pages) Version: 0407 Description: Adaptor frames and options for other than lay in ceilings. |
|
Minimum Security Lattice
9/4/07 (PDF: 310KB / 1 pages) Version: 0294 Description: For minimum security areas of correctional facilities, prisons, psychiatric hospitals and manufacturing plants. |
|
Alternatives for Minimum Flow Stops
9/4/07 (PDF: 59KB / 2 pages) Version: 0102 Description: Minimum flow options for the Model TF Therma-Fuser diffuser. |
|
TF-HC No Heat
9/4/07 (PDF: 58KB / 2 pages) Version: 0394 Description: A VAV diffuser that stays closed when the supply air is warm. |
|
TF-HC Limited Heat
9/4/07 (PDF: 81KB / 2 pages) Version: 0604 Description: A VAV diffuser where the maximum air volume in heating may be adjusted from 0-100% of capacity. |
|
|
TF Submittals
6/16/08 (PDF: 116KB / 2 pages) Version: 0611 Description: General submittal for the Model TF Therma-Fuser Diffuser |
|
|
TF-HC Specification
6/6/09 (PDF: 54KB / 1 pages) Version: 1006 Description: Performance specification suitable for Section 23 36 16 Variable-Air-Volume Units of the CSI MasterFormat. |
|
|
TF-HC Dimensions
6/9/09 (PDF: 64KB / 1 pages) Version: 1006 Description: Size and dimensions. |
|
|
TF-RA Pressure Drop - I-P
9/4/07 (PDF: 76KB / 1 pages) Version: 0507 Description: Static pressure and air volume guide (inch-pound) for the TF-RA matching return air diffuser. |
|
TF-RA Pressure Drop - SI
9/4/07 (PDF: 75KB / 1 pages) Version: 0507 Description: Static pressure and air volume guide (metric) for the TF-RA matching return air diffuser. |
|
|
TF-HC Low Stratification Heating
9/4/07 (PDF: 164KB / 4 pages) Version: 1188 Description: The best way to heat from the ceiling. |
|
|
Adjusting Changeover Element
6/17/08 (PDF: 620KB / 2 pages) Version: 1082 Description: The changeover element and adjusting screw were factory adjusted and sealed with Loctite. Re-adjustment is not necessare unless the seal has been broken or the element is replaced. |
|
|
|
VA Brochure
9/4/07 (PDF: 956KB / 4 pages) Version: 0497 Description: Benefits, how it works, features, performance and system design for the Model VA Ventilation Air Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
Ceiling Approaches
9/4/07 (PDF: 1MB / 6 pages) Version: 0407 Description: Adaptor frames and options for other than lay in ceilings. |
|
|
|
|
TK Brochure
9/4/07 (PDF: 859KB / 4 pages) Version: 0808 Description: Benefits, how it works, features, performance and system design for the Model TK Therma-Fuser diffuser. |
|
|
TK IBM
9/4/07 (PDF: 744KB / 5 pages) Version: 603 Description: Installation, balancing, maintenance and operation of the Model TK Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
Ceiling Frames TK, TN
9/4/07 (PDF: 31KB / 1 pages) Version: 0896 Description: Adaptor frames and options for other than lay in ceilings. |
|
|
|
TN Brochure
3/2/09 (PDF: 432KB / 4 pages) Version: 0911 Description: Benefits, how it works, features, performance and system design for the Model TN Therma-Fuser diffuser. |
|
|
TN IBM
9/4/07 (PDF: 176KB / 2 pages) Version: 0796 Description: Installation, balancing, maintenance and operation of the Model TN Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
Ceiling Frames TK, TN
9/4/07 (PDF: 31KB / 1 pages) Version: 0896 Description: Adaptor frames and options for other than lay in ceilings. |
|
|
|
|
TL Brochure
6/30/08 (PDF: 2MB / 6 pages) Version: 0806 Description: Benefits, how it works, features, performance and system design for the Model TL Therma-Fuser diffuser. |
|
|
TL IBM
9/4/07 (PDF: 644KB / 6 pages) Version: 0703 Description: Installation, balancing, maintenance and operation of the Model TL Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
Linear Ceiling Approaches
1/20/09 (PDF: 485KB / 6 pages) Version: 0809 Description: Installation options and instructions for the TL linear slot diffuser. |
|
|
TL Submittal
9/4/07 (PDF: 134KB / 2 pages) Version: 0611 Description: General submittal for the Model TL Therma-Fuser diffuser. |
|
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
|
|
TLW Brochure
9/4/07 (PDF: 1MB / 6 pages) Version: 0605 Description: Benefits, how it works, features, performance and system design for the Model TLW Therma-Fuser diffuser. |
|
|
TLW IBM
9/4/07 (PDF: 1MB / 6 pages) Version: 0605 Description: Installation, balancing, maintenance and operation of the Model TLW Therma-Fuser diffuser. |
|
|
Digital Remote Wall Adjuster Brochure
9/4/07 (PDF: 350KB / 2 pages) Version: 0505 Description: Allows the occupant to easily adjust the temperature set point of the thermostat(s) located in the Therma-Fuser diffuser. |
|
Digital Remote Wall Adjuster IBM
5/26/09 (PDF: 1MB / 4 pages) Version: 0905 Description: Installation, operation and maintenance of the Digital Wall Adjuster. |
|
|
|
|
E-PIM Brochure
9/4/07 (PDF: 73KB / 2 pages) Version: 0505 Description: Benefits, how it works, features, performance and system design for the E-PIM static pressure controller. |
|
|
E-PIM IBM
9/4/07 (PDF: 291KB / 12 pages) Version: 0703 Description: Installation, balancing, maintenance and operation of the E-PIM static pressure controller. |
|
|
DDC Interoperable Therma-Fuser Diffuser Checklist
6/17/08 (PDF: 54KB / 2 pages) Version: 0611 Description: For those of you not overly familiar with interoperability, here are a few tips to get you started. |
|
Creation of a Stand Alone Lon Network
6/17/08 (PDF: 59KB / 2 pages) Version: Description: or How to Operate an E-Diffuser without a BAS |
|
|
|
EF Brochure
9/4/07 (PDF: 838KB / 4 pages) Version: 0604 Description: Benefits, how it works, features, performance and system design for the Model EF Therma-Fuser diffuser. |
|
|
EF IBM
9/4/07 (PDF: 312KB / 17 pages) Version: 0703 Description: Installation, balancing, maintenance and operation of the Model EF Therma-Fuser diffuser. |
|
|
Answers to the Most Commonly Asked Questions on the EF Unit
6/17/08 (PDF: 804KB / 2 pages) Version: 999 Description: EF FAQ |
|
LonMark Certification for EF Interoperable Therma-Fuser Modules
6/17/08 (PDF: 432KB / 2 pages) Version: 1199 Description: The EF has successfully passed the LonMark Conformance review. |
|
.XIF file and Plug-in for use wiht EF Therma-Fuser modules
6/17/08 (PDF: 398KB / 1 pages) Version: 1199 Description: The files aid in building the network and setting the initial configuration properties. |
|
EF Blow Patterns
6/17/08 (PDF: 190KB / 1 pages) Version: 700 Description: Blow patterns are now available for the EF interoperable Therma-Fuser diffusers. |
|
DDC Interoperable Therma-Fuser Diffuser Checklist
6/17/08 (PDF: 54KB / 2 pages) Version: 0611 Description: For those of you not overly familiar with interoperability, here are a few tips to get you started. |
|
Creation of a Stand Alone Lon Network
6/17/08 (PDF: 59KB / 2 pages) Version: Description: or How to Operate an E-Diffuser without a BAS |
|
EF XIF File
6/17/08 (Other: 4KB / 1 pages) Version: 0003 Description: XIF file for network creation |
|
EF Plugin File
6/17/08 (Other: 3MB / 1 pages) Version: 01 Description: Plugin file for network configuration |
|
Tridium Support Files
6/17/08 (Other: 57KB / 1 pages) Version: 0703 Description: Product support files for the Tridium Niagra Framework |
|
|
|
EL Brochure
9/4/07 (PDF: 576KB / 6 pages) Version: 0608 Description: Benefits, how it works, features, performance and system design for the Model EL Therma-Fuser diffuser. |
|
|
EL IBM
9/4/07 (PDF: 291KB / 15 pages) Version: 0703 Description: Installation, balancing, maintenance and operation of the Model EL Therma-Fuser diffuser. |
|
|
Answers to the Most Commonly Asked Questions on the EF Unit
6/17/08 (PDF: 804KB / 2 pages) Version: 999 Description: EF FAQ |
|
.XIF file and Plug-in for use wiht EF Therma-Fuser modules
6/17/08 (PDF: 398KB / 1 pages) Version: 1199 Description: The files aid in building the network and setting the initial configuration properties. |
|
DDC Interoperable Therma-Fuser Diffuser Checklist
6/17/08 (PDF: 54KB / 2 pages) Version: 0611 Description: For those of you not overly familiar with interoperability, here are a few tips to get you started. |
|
Creation of a Stand Alone Lon Network
6/17/08 (PDF: 59KB / 2 pages) Version: Description: or How to Operate an E-Diffuser without a BAS |
|
EF XIF File
6/17/08 (Other: 4KB / 1 pages) Version: 0003 Description: XIF file for network creation |
|
EF Plugin File
6/17/08 (Other: 3MB / 1 pages) Version: 01 Description: Plugin file for network configuration |
|
Tridium Support Files
6/17/08 (Other: 57KB / 1 pages) Version: 0703 Description: Product support files for the Tridium Niagra Framework |
|
|
|
ELW Brochure
9/4/07 (PDF: 707KB / 6 pages) Version: 0707 Description: Benefits, how it works, features, performance and system design for the Model ELW Therma-Fuser diffuser. |
|
|
ELW IBM
9/4/07 (PDF: 282KB / 15 pages) Version: 0703 Description: Installation, balancing, maintenance and operation of the Model ELW Therma-Fuser diffuser. |
|
|
Answers to the Most Commonly Asked Questions on the EF Unit
6/17/08 (PDF: 804KB / 2 pages) Version: 999 Description: EF FAQ |
|
.XIF file and Plug-in for use wiht EF Therma-Fuser modules
6/17/08 (PDF: 398KB / 1 pages) Version: 1199 Description: The files aid in building the network and setting the initial configuration properties. |
|
DDC Interoperable Therma-Fuser Diffuser Checklist
6/17/08 (PDF: 54KB / 2 pages) Version: 0611 Description: For those of you not overly familiar with interoperability, here are a few tips to get you started. |
|
Creation of a Stand Alone Lon Network
6/17/08 (PDF: 59KB / 2 pages) Version: Description: or How to Operate an E-Diffuser without a BAS |
|
EF XIF File
6/17/08 (Other: 4KB / 1 pages) Version: 0003 Description: XIF file for network creation |
|
EF Plugin File
6/17/08 (Other: 3MB / 1 pages) Version: 01 Description: Plugin file for network configuration |
|
Tridium Support Files
6/17/08 (Other: 57KB / 1 pages) Version: 0703 Description: Product support files for the Tridium Niagra Framework |
|
|
|
|
AZON-I & II-E Brochure
4/2/09 (PDF: 1MB / 4 pages) Version: 0901 Description: Benefits, how it works, features, performance and system design for the Acu-Zone I and II Electric Zone Heaters. |
|
AZON-II-W Brochure
4/2/09 (PDF: 3MB / 6 pages) Version: 0901 Description: Benefits, how it works, features, performance and system design for the AZON-II-W Hot Water Zone Heater. |
|
|
AZON-I-E IOM
1/28/09 (PDF: 277KB / 12 pages) Version: 0901 Description: Installation, operation and maintenance of the Acu-Zone I Electric Zone Heater. |
|
AZON-II-E IOM Square Rectangular
1/28/09 (PDF: 815KB / 15 pages) Version: 0901 Description: Installation, operation and maintenance of the Acu-Zone II E Square Rectangular Electric Zone Heater. |
|
AZON-II-E IOM Round
1/28/09 (PDF: 355KB / 13 pages) Version: 0901 Description: Installation, operation and maintenance of the Acu-Zone II Round Electric Zone Heater. |
|
AZON-II-W IOM
1/28/09 (PDF: 566KB / 6 pages) Version: 0901 Description: Installation, operation and maintenance of the Acu-Zone II Hot Water Zone Heater. |
|
AZON Application, Selection and Specification Manual
9/4/07 (PDF: 2MB / 35 pages) Version: 0603 Description: Application and selection of both the Acu-Zone I and Acu-Zone II Duct Heaters |
|
|
|
PIM Brochure
11/30/07 (PDF: 862KB / 4 pages) Version: 0711 Description: Benefits, how it works, features, performance and system design for the PIM static pressure controller. |
|
R-PIM Brochure
9/4/07 (PDF: 600KB / 4 pages) Version: 0511 Description: Benefits, how it works, features, performance and system design for the R-PIM static pressure controller. |
|
|
PIM IBM
9/4/07 (PDF: 616KB / 4 pages) Version: 0606 Description: Installation, balancing, maintenance and operation of the PIM static pressure controller. |
|
R-PIM IBM
9/4/07 (PDF: 93KB / 2 pages) Version: 0511 Description: Installation and operation of the R-PIM static pressure controller. |
|
|
R-PIM Options and Accessories
11/30/99 (PDF: 125KB / 4 pages) Version: 0606 Description: Options and accessories for the Round Pressure Independence Module |
|
|
R-PIM Performance Data
11/30/99 (PDF: 8MB / 32 pages) Version: 0606 Description: Air volume, pressure drop and noise performance data for the Round Pressure Independence Module |
|
|
PIM Range to 2.0"wg
6/16/08 (PDF: 67KB / 2 pages) Version: 0490 Description: The PIM can be supplied or field modified for a static pressure range of 0 2.0 in. w.g. |
|
Overriding the PIM
9/4/07 (PDF: 747KB / 1 pages) Version: 0491 Description: Shut off air to an un-occupied zone, isolation damper and open for system purge. |
|
PIM U.L. Transformer
6/17/08 (PDF: 293KB / 1 pages) Version: 490 Description: The line voltage side of the 120V PIM uses a U.L. recognized NEMA II energy limiting transformer. |
|
PIM and Negative Pressure
6/17/08 (PDF: 424KB / 2 pages) Version: 993 Description: To measure and control a negative pressure connect the PIM as shown. |
|
PIM Dampers Larger Than 48 x 36
6/17/08 (PDF: 280KB / 1 pages) Version: 196 Description: Dampers wider than 48in requires that two dampers be joined together and actuated as one damper. |
|
Dimension Change with Acutherm Supplied Dampers
6/17/08 (PDF: 221KB / 1 pages) Version: 602 Description: The frame depth of dampers supplied by Acutherm with PIM modules has changed from 4-1/4in to 5in. |
|
|
|
SMC Brochure
9/4/07 (PDF: 1MB / 6 pages) Version: 0608 Description: Benefits, how it works, features, performance and system design for the SMC system mode controller. |
|
|
SMC IBM
9/4/07 (PDF: 7MB / 8 pages) Version: 0810 Description: Installation, balancing, maintenance and operation of the SMC system mode controller. |
|
Clock Programming Instructions
10/27/08 (PDF: 226KB / 3 pages) Version: 0810 Description: Programming instructions for the new Grasslin clock. |
|
|
SMC Duct Heat Stations
6/16/08 (PDF: 2MB / 6 pages) Version: 501 Description: Energize up to five duct heat stations by adding a duct heat board. |
|
SMC Fan Powered Box
9/4/07 (PDF: 368KB / 6 pages) Version: 1197 Description: Energize up to five fan powered boxes by adding a duct heat board. |
|
|
SMC Record of Startup
9/4/07 (PDF: 93KB / 2 pages) Version: 0610 Description: Start up record sheet. |
|
Heat Pumps and the SMC
6/17/08 (PDF: 411KB / 2 pages) Version: 502 Description: When using an SMC to control a heat pump, find out if the heat pump needs a signal from teh thermostat for the reversing valve. |
|
Where to Use the SMC
6/17/08 (PDF: 598KB / 2 pages) Version: 1191 Description: The SMC is for controlling the source of heating and cooling when both are supplied through the same duct. |
|
Voltmeters and Test Clips
6/17/08 (PDF: 518KB / 2 pages) Version: 1291 Description: Setting the potentiometers does not require an expensive or highly sophisticated meter. |
|
|
|
|
Designing Modular VAV Systems
5/26/09 (PDF: 582KB / 12 pages) Version: 0905 Description: What a Therma-Fuser diffuser needs for optimum operation. |
|
Balancing Systems
9/4/07 (PDF: 3MB / 2 pages) Version: 1287 Description: All VAV systems are balanced at maximum air flow to achieve design air volume at each diffuser. |
|
Facts About VAV Heating
9/4/07 (PDF: 384KB / 2 pages) Version: 0409 Description: The key to successful heating from the ceiling is relatively high discharge velocity. |
|
Loop Duct Design
9/4/07 (PDF: 210KB / 4 pages) Version: 0883 Description: Advantages and design of a low velocity supply air loop duct. |
|
Essentials of a Modular VAV System
9/4/07 (PDF: 316KB / 2 pages) Version: 0409 Description: The four essential elements of a modular VAV system. |
|
Options of Static Pressure Control and Pressure Independence
9/4/07 (PDF: 339KB / 2 pages) Version: 0502 Description: Provide high enough static pressure to obtain the required air volume and limit the static pressure at both full flow and turndown to avoid diffuser noise. |
|
Constant Volume DX Units Including Heat Pumps Sub Zoned with Therma-Fuser Diffusers
9/4/07 (PDF: 310KB / 2 pages) Version: 0504 Description: How to design a Constant Volume DX or Heat Pump Therma-Fuser diffuser system. |
|
Duct Heat Sub Zoned with Therma-Fuser Diffusers
3/28/08 (PDF: 198KB / 2 pages) Version: 0504 Description: How to design a Duct Heat Therma-Fuser diffuser system. |
|
Air Handling and Fan Coil Units Sub Zoned with Therma-Fuser Diffusers
11/30/07 (PDF: 289KB / 2 pages) Version: 0711 Description: How to design an Air Handling or Fan Coil Unit Therma-Fuser diffuser system. |
|
"Texas Multizone" Zones Sub Zoned with Therma-Fuser Diffusers
9/4/07 (PDF: 554KB / 4 pages) Version: 0709 Description: How to design a Texas Multizone Therma-Fuser diffuser system. |
|
Two Deck Multizone Systems
9/4/07 (PDF: 1MB / 4 pages) Version: 0710 Description: How to design a Two Deck Multizone Therma-Fuser diffuser system. |
|
Dual Duct Boxes Sub Zoned with Therma-Fuser Diffusers
9/4/07 (PDF: 488KB / 6 pages) Version: 0504 Description: How to design a Dual Duct (Double Duct) Box Therma-Fuser diffuser system. |
|
VAV Boxes Sub Zoned with Therma-Fuser Diffusers
3/2/09 (PDF: 704KB / 2 pages) Version: 0912 Description: How to design a VAV Box Therma-Fuser diffuser system. |
|
VAV Reheat Boxes Sub Zoned with Therma-Fuser Diffusers
3/2/09 (PDF: 2MB / 4 pages) Version: 0912 Description: How to design a VAV Reheat Box Therma-Fuser diffuser system. |
|
Continuous Fan Powered Boxes Sub Zoned with Therma-Fuser Diffusers
3/28/08 (PDF: 229KB / 2 pages) Version: 0606 Description: How to design a Continuous Fan Powered Box Therma-Fuser diffuser system. |
|
Intermittent Fan Powered Boxes Sub Zoned with Therma-Fuser Diffusers
9/4/07 (PDF: 463KB / 4 pages) Version: 0410 Description: How to design an Intermittent Fan Powered Box Therma-Fuser diffuser system. |
|
Purging Cold Air From Ducts When Heating
6/17/08 (PDF: 776KB / 1 pages) Version: 484 Description: When designing systems consideration must be given to how fast the ducts can be purged of cold air when heaitng begins. |
|
Why Zone Interiors
6/17/08 (PDF: 603KB / 2 pages) Version: 992 Description: Office buildings require a zone for each work station that will comfortably satisfy the different heat loads. |
|
Heating Supply Temperature
6/17/08 (PDF: 599KB / 2 pages) Version: 295 Description: Why heating supply temperatures should be as low as possible and estimates of what the actual heating temperature should be for your location. |
|
Part Therma-Fuser Master Zones
6/17/08 (PDF: 874KB / 2 pages) Version: 1091 Description: When only part of a master zone has Therma-Fuser diffusers use these guidelines. |
|
|
Variable Air Systems Optimized
12/31/09 (PDF: 1MB / 20 pages) Version: 0804 Description: Overview of company and products |
|
Energy Modeling Guide for Therma-Fuser systems
11/30/99 (PDF: 4MB / 8 pages) Version: 1004 Description: The Energy Modeling Guide is a quick reference showing step by step how easy it is to energy model a Therma-Fuser system. The guide references the EnergyPro software for examples, but the steps are equally applicable to most other energy modeling software. |
|
We Make Offices More Comfortable
6/5/08 (PDF: 3MB / 6 pages) Version: 0899 Description: Individual temperature control for dynamic loads and short paybacks. |
|
The Case for Individual Temperature Control
9/4/07 (PDF: 264KB / 2 pages) Version: 0503 Description: Individual temperature control for random loads, reduce complaints, meet expectations, save energy, increase productivity and rent unleased space. |
|
Quick Reference Guide
9/4/07 (PDF: 1MB / 2 pages) Version: 0606 Description: Summary of complete product line. |
|
Superior Air Distribution
9/4/07 (PDF: 489KB / 6 pages) Version: 402 Description: Therma-Fuser diffusers vary the discharge opening as they vary the air volume |
|
Facts About VAV Heating
9/4/07 (PDF: 384KB / 2 pages) Version: 0409 Description: The key to successful heating from the ceiling is relatively high discharge velocity. |
|
Lowest Cost Per Zone
9/4/07 (PDF: 2MB / 4 pages) Version: 0294 Description: Therma-Fuser diffusers provide the lowest installed cost per zone of control. |
|
Lowest Energy VAV Terminal
3/2/09 (PDF: 3MB / 4 pages) Version: 0911 Description: Independent studies confirm that Therma-Fuser Diffusers are the lowest environmental impact - green - VAV terminals. |
|
Low to No Maintenance
9/4/07 (PDF: 2MB / 2 pages) Version: 0494 Description: Therma-Fuser diffusers require low - maybe no - maintenance. |
|
Easily Adapts to Office Layout Changes
6/5/08 (PDF: 2MB / 2 pages) Version: 0498 Description: Therma-Fuser diffusers are more adaptable to office change with no zones being split when office walls are moved. |
|
The Best Solution to Comfort Complaints:
6/5/08 (PDF: 354KB / 1 pages) Version: 0410 Description: Solve comfort complaints with quick and easy installation. |
|
Aerospace Technology
9/4/07 (PDF: 45KB / 1 pages) Version: 0502 Description: Acutherm thermostats are a more robust version of those used by the aerospace industry for jet engines. |
|
Why a Thermostat is In Each Therma-Fuser Diffuser
9/4/07 (PDF: 42KB / 1 pages) Version: 0186 Description: Personalized temperature selection. |
|
EPA Program Impacts Office Zoning
9/4/07 (PDF: 6MB / 6 pages) Version: 0197 Description: Need for individual temperature control due to the distribution of internal heat gains because of the Energy Star Office Equipment Program. |
|
Demonstrate Superior Air Distribution in Your Own Conference Room
6/17/08 (PDF: 728KB / 2 pages) Version: 898 Description: Side by side smoke test of Therma-Fuser diffuser vs. perforated grill. |
|
Therma-Fuser VAV is featured in an article about "Reinventing HVAC Design for Green Buildings"
6/17/08 (PDF: 341KB / 1 pages) Version: 301 Description: Therma-Fuser VAV is included in a list of sustainable HVAC systems. |
|
Sustainable Design Guide
11/10/09 (PDF: 222KB / 6 pages) Version: 0911 Description: How a Therma-Fuser VAV Diffuser System Can Help Achieve Credits under the LEED 2009 Green Building Rating System |
|
Energy Study by Rumsey Engineers
11/30/99 (PDF: 1MB / 34 pages) Version: 1 Description: Detailed energy analysis comparing a VAV box system with a Therma-Fuser diffuser system. |
|
Energy Study by Bassett Consulting Engineers
11/30/99 (PDF: 332KB / 51 pages) Version: 1 Description: Detailed energy analysis comparing an active chilled beam system and a VAV box system with a Therma-Fuser diffuser system. |
|
Energy Study by C.A. Pieper Consulting Engineers
11/30/99 (PDF: 374KB / 9 pages) Version: 1 Description: Energy analysis of multi-room zoning vs. individual room temperature control |
|
|
Sample Jobs List
10/16/09 (PDF: 50KB / 4 pages) Version: 0910 Description: A selection of the many installations with Therma-Fuser diffusers. |
|
Tenant Comfort and Confirmed 20% Lower HVAC Maintenance Costs- A Developer's Dream
9/4/07 (PDF: 498KB / 2 pages) Version: 0505 Description: Almost no comfort complaints to follow up with Therma-Fuser VAV |
|
The Custom Comfort Cure
9/4/07 (PDF: 359KB / 4 pages) Version: 0901 Description: Complaints from building occupants have been significantly lower than other similar facilities without individual temperature control. |
|
Expensive Leaky Valve Maintenance Eliminated by Replacing Radiant Panels with Therma-Fuser VAV
9/4/07 (PDF: 186KB / 2 pages) Version: 0601 Description: Existing duct work used to provide individual temperature control. |
|
Corporate Mission More Important Than Cost
9/4/07 (PDF: 112KB / 2 pages) Version: 1000 Description: Have you caught up with this big change in priorities for corporate real estate and facilities management? |
|
Therma-Fuser VAV Diffusers Deliver Low-Temperature Air, Lower Costs
9/4/07 (PDF: 184KB / 2 pages) Version: 0399 Description: to West Market Street Office Building. 42 degree air comfortably introduced directly into rooms. |
|
Therma-Fuser VAV Diffusers Nine Years of Individual Space Temperature Control to Robbins AFB NCO Academy.
9/4/07 (PDF: 236KB / 2 pages) Version: 0498 Description: Simple installation, simple system, no maintenance. |
|
Community College Controls Costs and Temperatures with Modular VAV Systems
9/4/07 (PDF: 193KB / 2 pages) Version: 0198 Description: Seven SMC modules and PIM units control modular VAV system. |
|
Lake Amir Office Park Ends Complaints and Achieves 97 Percent Occupancy
9/4/07 (PDF: 3MB / 2 pages) Version: 0496 Description: Therma-Fuser diffusers eliminate balancing act between offices. |
|
Dade County Employees Vote for Modular VAV
9/4/07 (PDF: 2MB / 2 pages) Version: 1094 Description: Therma-Fuser VAV diffusers bring comfort to county office building. |
|
Temperature-Sensitive Building Tenants Get What They Want with Therma-Fuser modular VAV system.
9/4/07 (PDF: 2MB / 2 pages) Version: 0194 Description: Therma-Fuser diffusers enable us to maintain very exact but different temperatures. |
|
Georgia School for the Deaf Finds Economical Way to Air Condition Dorms
9/4/07 (PDF: 2MB / 1 pages) Version: 1093 Description: Modular VAV terminal from Acutherm key to new system. |
|
Twenty Year Old Building Goes From 22 Percent Occupancy to Fully Tenanted in 16 Months
9/4/07 (PDF: 3MB / 2 pages) Version: 0296 Description: Texas multizones converted from 130 to 1800+ zones. |
|
Schools Converted from Open Plan to Classrooms Zoned with Therma-Fuser VAV Diffusers
9/4/07 (PDF: 3MB / 2 pages) Version: 0992 Description: The Therma-Fuser diffusers let us create lots of zones at a low cost. |
|
Dallas School Cuts HVAC Maintenance by Two Thirds
9/4/07 (PDF: 3MB / 2 pages) Version: 0692 Description: Therma-Fuser VAV diffusers offer low first cost, reduce maintenance significantly. |
|
A New Concept in Design and Comfort: The Riverside Office Center
9/4/07 (PDF: 3MB / 2 pages) Version: 0592 Description: Special mechanical design delivers individual temperature control. |
|
Electronics Factory Slashes Energy Costs, Controls Temperature and Humidity With Modular VAV Upgrade
9/4/07 (PDF: 2MB / 2 pages) Version: 1091 Description: Modular VAV proves as effective on the plant floor as in the office. |
|
Air Conditioning Contractor Selects Linear Therma-Fuser VAV Diffusers for His Own Offices
9/4/07 (PDF: 1MB / 1 pages) Version: 0491 Description: More comfortable, less expensive, quieter and cleaner than comparable VAV systems. |
|
Consulting Engineer Has Repeated Success with Therma-Fuser VAV Diffusers
8/6/08 (PDF: 2MB / 2 pages) Version: 390 Description: "Over the years we have found that thermally powered VAV makes clients happy." |
|
Thermally Powered VAV Reduces Operating Costs by More Than 50 Percent
9/4/07 (PDF: 2MB / 2 pages) Version: 1089 Description: Maintains Clean Room Environment for Electronics Manufacturer |
|
Ten Years of Reliability: Therma-Fuser Diffusers Provide VAV Comfort Without Repair or Replacement in California Office Building
9/4/07 (PDF: 1MB / 1 pages) Version: 0789 Description: Therma-Fuser VAV diffusers reduce first costs by 20 percent, maintenance costs by 10 percent. |
|
Historic Building Received State-Of-The-Art HVAC Retrofit
6/17/08 (PDF: 2MB / 1 pages) Version: 689 Description: Thermally Powered VAV Diffusers Help Reduce Operating Costs From $25,000 A Month to $13,000 A Month |
|
Solar Efficient Building Uses Energy and Cost Efficient Thermally Powered VAV Diffusers for Cooling
6/17/08 (PDF: 2MB / 1 pages) Version: 688 Description: Solar energy for heating and Therma-Fuser VAV diffusers to maximize cooling. |
|
New School Administration Building Wins Energy Awards for Design and Operation
6/17/08 (PDF: 2MB / 1 pages) Version: 388 Description: Thermally Powered VAV Diffusers from Acutherm Contribute to Energy Savings |
|
30 Year Old Low Pressure Duct System Serves Over 900 Zones
6/17/08 (PDF: 2MB / 1 pages) Version: 187 Description: in Philadelphia's Largest Bank PFSF Converts Old Newspaper Building into Energy Efficient Operations Center |
|
A Loaf of Bread, a Jug of Wine and Therma-Fuser VAV Diffusers
6/17/08 (PDF: 2MB / 1 pages) Version: 1286 Description: Provide Comfort for Minimal Cost at the Christian Brothers Winery |
|
Constant Volume System Upgraded for VAV Energy Savings
6/17/08 (PDF: 2MB / 1 pages) Version: 1086 Description: by Replacing Diffusers and Adding Variable Frequency Drive |
|
Special VAV Diffusers Provide Classroom Comfort
6/17/08 (PDF: 2MB / 1 pages) Version: 986 Description: to Cottonwood Creek Elementary Students Acutherm's Therma-Fuser VAV Diffusers Maintain Temperatures to Within 2 Degrees, Reduce Maintenance Calls by 75 Percent |
|
Thirteen Years Later: VAV Modular Diffusers Still Work Fine. No Problems. Happy People.
9/4/07 (PDF: 3MB / 2 pages) Version: 0698 Description: No maintenance, no replacements, no temperature fluctuations with Therma-Fuser TF-HC modular VAV diffusers. |
|
Tulsa's Park Tower Keeps Cool With Therma-Fuser Diffusers
9/4/07 (PDF: 2MB / 1 pages) Version: 0386 Description: One successful project leads to another for Acutherm product. |
|
Prestige Building Provides Executive Comfort
6/17/08 (PDF: 2MB / 1 pages) Version: 186 Description: With Cost-Effective Air Conditioning System Therma-Fuser VAV Diffusers Reduce Cost of Heating and Cooling System by 20 Percent |
|
Lack of Ceiling Space Resolved by Running Ducts Between Joists to Therma-Fuser VAV Diffusers.
9/4/07 (PDF: 1MB / 1 pages) Version: 1285 Description: Unique vertical duct system and Therma-Fuser VAV diffusers accommodate minimal ceiling space at Applause, Inc. |
|
Parallel Duct Work Increases Air Volume
6/17/08 (PDF: 1MB / 1 pages) Version: 1185 Description: When Upgrading For Individual Temperature Control Therma-Fuser TF-HC Units Provide Flexibility and Low Maintenance as Department Store Converts to Office Space. |
|
Large Constant Volume System In Turn-Of-The-Century Bank Converted
9/4/07 (PDF: 1MB / 1 pages) Version: 0985 Description: to a zone per room with Therma-Fuser VAV Diffusers. |
|
VAV Upgrade Provides Temperature Control
6/17/08 (PDF: 1MB / 1 pages) Version: 985 Description: in Variety of Uses: Lobby, Computer Rooms and Labratories |
|
1200 Zones of Temperature Control with No Replacements Due to Failure Since 1981
9/4/07 (PDF: 962KB / 1 pages) Version: 1089 Description: Sophistication and simplicity are cornerstone's of New York's 767 Third Avenue. |
|
Energy Savings to Bank On
6/17/08 (PDF: 1MB / 1 pages) Version: 785 Description: Charleston National Bank reduces installation costs by 40 percent, provides individual temperature control with Therma-Fuser installation. |
|
Therma-Fuser Diffusers Contribute to Energy Savings
6/17/08 (PDF: 1MB / 1 pages) Version: 785 Description: in ASHRAE Award Winning Installations |
|
Oxford Development Company
9/4/07 (PDF: 131KB / 2 pages) Version: 1284 Description: VAV diffuser plays key role in reducing cost of low-pressure heating/cooling system for tenant space. |
|
|
Low Pressure Rectangular Duct Costs
9/4/07 (PDF: 79KB / 2 pages) Version: 0612 Description: The least expensive ductwork for a job is a low pressure rectangular duct. |